Sungshin Industrial's HEAT TRACING (Anti-icing) system was designed and developed so that the surface of the Eliminator of the Water Separator Louver installed in the ventilation system of a ship operating in the Arctic Ocean (zero to 50°C below zero) does not freeze. The anti-icing system is specially designed and designed to install the heating cable directly on the water separator louver's eliminator. The louver eliminator (profile) performs an optimized design in the R&D room to maximize water separation and heat transfer efficiency, and the self-designed model is improved and repeatedly tested in the cold room test facility until the test results are satisfactory. It's possible.

· Cold room test equipment can test from room temperature to minus 50℃.

-   Sungshin Industrial's anti-icing system will be continuously improved and developed by the R&D department.